Blog Preview
Periodic testing of immersion suit and anti exposure suits seams and closures - reg.
Applicable to:
All Indian-flagged ships
Effective Date:
31st May 2017
Superseded Circulars:
None
Key Changes and Requirements
1. Periodic Testing Requirements
Immersion suits and anti-exposure suits must be inspected monthly. Pressure tests are required to maintain their strength and water tightness:
- Frequency: Every three years for suits under 10 years, and every alternate year for suits over 10 years.
- Method: Air pressure test in accordance with IMO Circular MSC/Cir.1114.
2. Approved Test Stations and Personnel
Pressure tests should be carried out at:
- Option 1: DGS-approved life raft service stations in India or IACS class-approved service stations outside India.
- Option 2: Shipboard personnel with minimum operational level foreign-going certificate of competency, approved by the company with the approval of the Nautical Advisor to the Government of India.
II/4 SOLAS Regulation
Important Note
Failure to comply with these testing requirements may result in non-compliance with SOLAS regulations and may affect the safety of the ship and its crew.