Blog Preview

Submission of documents for renewal of approval as FFA and LSA service stations.

Applicable to: All Fire Fighting Appliances (FFA) and Lifeboats, Launching appliances and On load release gear (LSA) service stations.
Effective Date: 20th March 2014
Superseded Circulars: None mentioned

Key Changes and Requirements

1. Periodical Statements and Renewal Procedure

Service stations must submit 6-monthly statements of jobs carried out, along with signed Customer Feedback Forms, within one month of each 6-month period. Non-submission of feedback forms may result in certificate suspension.

  • Renewal Application: Submit at least 3 months before expiry. Late applications may not be entertained.
  • Documents: Submit as per respective checklists available on DGS website.
  • Measuring Instruments: Calibrate at NABL accredited labs at intervals specified by the lab, ISO standards, or every 2 years, whichever is least.
II/4  Valid training certificate for service engineers is mandatory for LSA service stations.
Download official PDF

Want to learn and share your knowledge about the maritime world?

Explore the Blog app on Navvyx - Get maritime insights from across the world in one place.